Logo do repositório
Tudo no RIUFPA
Documentos
Contato
Sobre
Ajuda
  • Português do Brasil
  • English
  • Español
  • Français
Entrar
Novo usuário? Clique aqui para cadastrar. Esqueceu sua senha?
  1. Início
  2. Pesquisar por Autor

Navegando por Autor "MULLER, Renata Medeiros Lobo"

Filtrar resultados informando as primeiras letras
Agora exibindo 1 - 1 de 1
  • Resultados por página
  • Opções de Ordenação
  • Carregando...
    Imagem de Miniatura
    ItemAcesso aberto (Open Access)
    Técnicas voltamétricas com eletrodo de filme de bismuto modificado com edta e ebt para determinação de Ca2+ e Mg2+ em biodiesel
    (Universidade Federal do Pará, 2016-08-19) MULLER, Renata Medeiros Lobo; MARQUES, Aldalea Lopes Brandes; http://lattes.cnpq.br/0121030502015990; MÜLLER, Regina Celi Sarkis; http://lattes.cnpq.br/654941494386147
    This study presents the development of alternative electrochemical methods for the determination of Mg2+ and Ca2+ through voltammetry technique of adsorptive stripping voltammetry (VAdR) with anodic scan. Bismuth film electrode modified with eriochrome black-T (EBT) was used for modification of the electrode in the determination of Mg2+ in the pulse differential mode (DPAdSV), while EDTA has been used for determination of Ca2+ in wave mode square (SWAdSV). The determination of Mg2+ was performed using acetate buffer (0.1 mol L-1) at pH = 4.5, EBT as supporting electrolyte and 1.0 x 10-3 mol L-1 as a binder. Successive additions of aliquots of the stock solution were made Mg2+ 1.0 x 10-3 mol L-1 so that the ion was pre-concentrated on the sensor surface under the following conditions optimized voltammetric: deposition potential (EDEP) = - 1.0 V; Pre time - concentration (Tpre) = 120 s; scan speed (v) = 0.050 V s-1; pulse amplitude (Amp) = 0.1 V. The complex formed Mg2+ EBT showed a peak current of about - 0.6 V. The determination of Ca2+ was made using ammonium buffer (0.01 mol L-1) at pH 9.4, as supporting electrolyte and EDTA 1.0 x 10-2 mol L-1 as a binder under the following optimum conditions: deposition potential (EDEP) = -1.0 V; preconcentration time (Tpre) = 90 sec; frequency (freq.) = 15 Hz; width = 0,075V and Step E) = 0.004 V. The complex formed Ca2+ EDTA showed a peak current of approximately - 0.2 V. The result was consistent statistically considering t -test for a 95% confidence level. The levels were lower CV of 11.0% (Mg2+ and Ca2+), recoveries were in the range 95.0 to 108.0% (Mg2+) and from 97.8 to 105.0% (Ca2+) and the values of detection limits were 1.05 x 10-6 mol L-1 (Mg2+) and 2.8 x 10-7 mol L-1 (Ca2+), and quantitation 3.51 x 10-6 mol L-1 (Mg2+) and 9.46 x 10-7 mol L-1 (Ca2+) for the samples analyzed, showing good accuracy and sensitivity of the proposed method. The values obtained for the samples ranged from 1.47 x 10-5 ± 1.28 x 10-6 mol L-1 (Mg2+) and 5.57 x 10-6 ± 3.77 x 10-7 mol L-1 (Ca2+) on samples of biodiesel. The determination of metals such as Ca2+ and Mg2+ by electrochemical techniques with chemically modified electrodes has as main advantages its detectability and the selectivity.
Logo do RepositórioLogo do Repositório
Nossas Redes:

DSpace software copyright © 2002-2025 LYRASIS

  • Configurações de Cookies
  • Política de Privacidade
  • Termos de Uso
  • Entre em Contato
Brasão UFPA