Logo do repositório
Tudo no RIUFPA
Documentos
Contato
Sobre
Ajuda
  • Português do Brasil
  • English
  • Español
  • Français
Entrar
Novo usuário? Clique aqui para cadastrar. Esqueceu sua senha?
  1. Início
  2. Pesquisar por Assunto

Navegando por Assunto "Buildings"

Filtrar resultados informando as primeiras letras
Agora exibindo 1 - 5 de 5
  • Resultados por página
  • Opções de Ordenação
  • Carregando...
    Imagem de Miniatura
    ItemAcesso aberto (Open Access)
    Análise de parâmetros globais de projeto em edifícios com estrutura de concreto armado
    (Universidade Federal do Pará, 2015-12-22) VIEIRA, Vitor Vinicius dos Santos; VELOSO, Luís Augusto Conte Mendes; http://lattes.cnpq.br/9476653308517248
    The verification of reinforced concrete buildings is carried out by local analysis and by global analysis. In the local analysis are evaluated the effects of deformations in the isolated elements. Already in the overall analysis of the behavior is evaluated considered the structure as a whole. Normally, this overall verification is done through design parameters, which allow to maintain control of problems that can affect the safety or performance of buildings of reinforced concrete. By means of computer systems, it’s possible to obtain, fairly quickly, a series of parameters that offer virtually complete diagnostic of the answers that the structures will present when external actions submitted, like the wind or the vertical loads. Howeverit is not enough process structural models and get results, it is necessary to interpret what these mean and verify its validity. Therefore, this study was done with the intention to contribute with the referring studies the overall analysis of the structures, based on the design parameters to know: 𝛾𝑧 and 𝑅𝑀2𝑀1 coefficients, overall critical load factor of buckling, horizontal displacements, fundamental frequency and acceleration. Are studied several cases of idealized structures, with the objective to evaluate the relation between these parameters and propose simplified equations for calculating the overall critical load factor and the fundamental frequency from the 𝛾𝑧 coefficient. Furthermore, are analyze some real building structures aiming to evaluate the proposed equations and draw comparisons with the limits recommended by Brazilian standards. For the processing of structures were used two analysis programs, the TQS and the SAP2000. Generally speaking, the equations that relate the 𝛾𝑧 coefficient with the critical load factor and with the fundamental frequency showed satisfactory results. For displacement and acceleration, could not establish equations due to inexistence of relation of these as the 𝛾𝑧. As for the normative limits, found to be that even structures that fulfill the safety criteria for the overall instability, nevertheless these may present problems related to excessive horizontal displacements and vibrations perceptible to the human being.
  • Carregando...
    Imagem de Miniatura
    ItemAcesso aberto (Open Access)
    Avaliação através do desempenho térmico de edificação verticalizada em Belém-PA
    (Universidade Federal do Pará, 2013-04-01) VINAGRE, Natália Daniele de Lima; PERDIGÃO, Ana Kláudia de Almeida Viana; TOSTES, Maria Emília de Lima; http://lattes.cnpq.br/4197618044519148; http://lattes.cnpq.br/9009878908080486
    This dissertation studies the thermal performance of materials in a vertical facade building in the city of Belém - PA, Brazil. This work aims to contribute to the study of the thermal performance and efficiency of materials used in residential buildings of the vertical envelopment, between opaque elements, two types of materials currently very used in construction were selected, painting and ceramic coating. It also studies the influence of the height of the building on its thermal performance and energy efficiency. The study was conducted with the use of computational modeling in EnergyPlus code that evaluates the thermal performance of the building, the influence of the height at the same energy efficiency. Compares the thermal performance of the two selected materials, it was found that the ceramic coating presented building with the average internal temperature of 0.42 ° C above the temperature at the building painted, hence less thermal performance. The influence of the height of the floor did not produce a significant variation in internal temperature, because its increase, small decrease occurred in the internal temperature with thermal gradient of about -0.07 º C / m due to the wind speed is greater when more higher the pavement. It is also considered for this study as passive natural ventilation strategy for the building under study, according to the analysis of Bioclimatic chart Givoni contribute positively to the condition of the internal temperature and humidity, and consequently the user.
  • Carregando...
    Imagem de Miniatura
    ItemAcesso aberto (Open Access)
    Desempenho acústico das edificações segundo a NBR 15575 (ABNT, 2013): desempenho das vedações e validação dos requisitos normativos com base na opinião dos usuários
    (Universidade Federal do Pará, 2016-03-18) SANTANA, Wylliam Bessa; PICANÇO, Marcelo de Souza; http://lattes.cnpq.br/4535052395600357
    With the growth of large urban centers in Brazil, the population density and the need for housing led to high demand for semi-detached homes and apartment houses with numerous apartments, however, with the passage of time they became the result of user complaints in consequence of the low performance of the buildings. The normalization of the performance of the buildings was necessary. Several international standards address the issue, but only in 2013 was published the Brazilian standard of buildings performance NBR 15575 (ABNT, 2013), stipulating among other things, requirements for acoustic performance of internal and external walls, and slabs about the noise impact and air. However, there are some questions, such as: does the current construction typology meet these performance acoustic criteria? Are these criteria suitable? Among to answer these questions, field tests and questionnaires were performed with residents. Among the seals whose acoustic performance is required, the results show the inner walls are more distant to meet these criteria, and the external meet with difficulty, even as perceived by users. About the regulatory requirements for acoustic performance, are significant the annoyed levels generated by impact loads on slabs, highlighting the low accuracy, and even more worrying that the latter is the fact in not require acoustic performance criteria regarding the impact noise between walls, highlighted by the vast majority of respondents as the main source of noise.
  • Carregando...
    Imagem de Miniatura
    ItemAcesso aberto (Open Access)
    Estudo numérico-experimental da influência da alvenaria de vedação na rigidez de edifícios de concreto armado
    (Universidade Federal do Pará, 2015-10-02) NASCIMENTO, Adauto Cezar Rosa do; VELOSO, Luís Augusto Conte Mendes; http://lattes.cnpq.br/9476653308517248
    In the practice of engineering design, the presence of masonry infill in framed structures of reinforced concrete buildings is considered only as a infill component or partition of an ambiente, in other words, the masonry infill is considered as a non-structural purpose element. Although the masonry be treated as a non-structural component, they are connected to the structural system, therefore is expected that they exert some influence in the behavior of the structure still their stiffening effects in buildings have normally been ignored by design engineers. The focus of this research is assess the masonry infill influence in the lateral stiffness of reinforced concrete tall buildings located in Belém (PA). For this purpose, the ambient vibration of two buildings was measured with accelerometers in order to determine their natural frequency. In addition, computational models of the buildings were made to assess the influence of the infill panels using equivalent diagonal strut method and considering the infill panels as shell elements. The principal comparisons between the computational models and experimental results were based on mode of vibration and natural frequency of the buildings. Significant global stiffness of building based on experimental frequency suggest that model more realistic is the model with infill panels modelled as shell elements.
  • Carregando...
    Imagem de Miniatura
    ItemAcesso aberto (Open Access)
    Patologias em fachadas: análises de casos na Universidade Federal do Pará
    (Universidade Federal do Pará, 2014-03-28) CARVALHO, Isabella Chaves; PICANÇO, Marcelo de Souza; http://lattes.cnpq.br/4535052395600357; MACEDO, Alcebíades Negrão; http://lattes.cnpq.br/8313864897400179
    The system of external cladding of the building acts as a protective layer and contributes to the proper aspect. The facade is subject to the action of agents of degradation as one of the most exposed areas of the building, with the presence of pathology becoming responsible for high repair costs. Research suggests as a general goal, assess conditions affecting building facades of higher education in the Federal University of Pará, guided by a theoretical basis (literature review) responsible for the first information on the subject. To such as research methodology, we sought to first do a physical survey of facades of 30 buildings in UFPA, identifying cadastral records in the main degradation mechanisms. Then, after quantify / qualify the anomalies present in the sample and point out the most critical building with key injuries and their causes, listed up to this, basic intervention measures in order to solve efficiently the problem caused by proposing a document that acts as technical support for inspection of facades generally. We also used the test to characterize samples in order to prove the origins of those damages which at first could not identify the cause. The results showed that the analyzed buildings have pathological damage of different nature and degree of complexity, ranging from the most complex requiring specific tests to discover their origin, even the most simple, with scheduled maintenance can be eliminated. We conclude that much of the damage happen by human negligence, but that even with an emphasis on quality of execution in facades, there is no way rule out failures or ignore the time of use and the actions of external factors lead to degradation Nature of the building. We conclude that much of the damage happen by human negligence, but that even with an emphasis on quality of execution in facades, there is no way to reject the hypothesis failures or ignore the time of use and the actions of external factors lead to natural degradation of the building. Therefore, to prevent the early onset of pathologies in facades, bringing its useful life and reducing extra costs, it is suggested, implementation procedures based on technical standards enforcement of them, following project criteria and presenting periodic inspections so that preventive measures are taken in apt time.
Logo do RepositórioLogo do Repositório
Nossas Redes:

DSpace software copyright © 2002-2025 LYRASIS

  • Configurações de Cookies
  • Política de Privacidade
  • Termos de Uso
  • Entre em Contato
Brasão UFPA