Logo do repositório
Tudo no RIUFPA
Documentos
Contato
Sobre
Ajuda
  • Português do Brasil
  • English
  • Español
  • Français
Entrar
Novo usuário? Clique aqui para cadastrar. Esqueceu sua senha?
  1. Início
  2. Pesquisar por Assunto

Navegando por Assunto "Carbonation"

Filtrar resultados informando as primeiras letras
Agora exibindo 1 - 1 de 1
  • Resultados por página
  • Opções de Ordenação
  • Carregando...
    Imagem de Miniatura
    ItemAcesso aberto (Open Access)
    Desenvolvimento de unidade piloto de transferência de massa gás/líquido: redução da reatividade do resíduo da indústria de alumina através da reação com gases de combustão
    (Universidade Federal do Pará, 2013-02) VENANCIO, Luis Carlos Alves; SOUZA, José Antônio da Silva; http://lattes.cnpq.br/6157348947425968; MACÊDO, Emanuel Negrão; http://lattes.cnpq.br/8718370108324505
    The bauxite refining using the Bayer process produces 0.7 to 2.0 tons of the residue known as red mud and about 1.0 ton of CO2 for each ton of alumina produced. The bauxite residue, although not particularly toxic, poses risks to the environment due to its large volume and reactivity. According to the latest technology, part of the moisture is removed and it is stacked on sealed areas specially constructed. More than 95% of the bauxite residue that has been produced (2.6 Bt until 2007) was discarded, especially in ponds on land. This thesis shows the design, construction and operation of a pilot scale gas liquid mass transfer unity with the objective of testing the reduction of the reactivity of the bauxite residue through a reaction with flue gas. As an additional gain, there is a reduction of carbon dioxide and sulfur dioxide emissions. This unity, with three reactors, was designed in order to consume minimal power, process the effluent as efficiently as possible and minimize the investment cost. Twenty-five experiments were realized with duration from 80 to 520 minutes each. The gases were analyzed at the entry and exit with electrochemical cells and non-dispersive infrared sensors. The pH was monitored during and after the reaction in order to evaluate the short and long-term results as well as the stability of the reactions. It was demonstrated the viability of reacting the bauxite residue with the flue gas from the refinery without previous processing with the stabilization pH reaching 10.5.
Logo do RepositórioLogo do Repositório
Nossas Redes:

DSpace software copyright © 2002-2025 LYRASIS

  • Configurações de Cookies
  • Política de Privacidade
  • Termos de Uso
  • Entre em Contato
Brasão UFPA