Navegando por Assunto "Concrete slabs"
Agora exibindo 1 - 2 de 2
- Resultados por página
- Opções de Ordenação
Item Acesso aberto (Open Access) Análise do efeito da retangularidade dos pilares nos critérios normativos de dimensionamento à punção em lajes lisas de concreto armado(Universidade Federal do Pará, 2013-10-22) PAIVA, Odilson da Silva de; OLIVEIRA, Dênio Ramam Carvalho de; http://lattes.cnpq.br/1324105476558186The system with flat slabs that do not depend on framework of beam has limited resistance by the resistance to punching shear, since the region of the slab-column is critical due to concentrated loads around the columns. The geometry of the columns is one of the factors influencing the distribution of stresses in the region of slab-column connection affecting turn in sizing the punching shear in the flat slabs. In this study we performed a thorough data collection that aims to collect into a single job the greatest possible amount of slabs covering the biggest names in the study of national and international punch, featuring a total of 131 slabs. A comparison was made between the main normative codes currently used Eurocode 2 (2004), NBR 6118 (2007), ACI 318 (2008) and CEB-FIP (2010). The experimental results were compared with those obtained theoretically taking into account the effects of retangularidade rate index in flat slabs of reinforced concrete, without punching shear reinforcement checking the adequacy, trustworthiness of each recommendation, analyzing the particularities of the rules and guidelines of each normative criterion.Item Acesso aberto (Open Access) Análise experimental de lajes nervuradas de concreto armado com viga faixa de altura variável(Universidade Federal do Pará, 2014-11-21) SACRAMENTO, Paulo Victor Prazeres; OLIVEIRA, Dênio Ramam Carvalho de; http://lattes.cnpq.br/1324105476558186The ribbed slabs have been widely used in the buildings it has several advantages in its execution and performance. In order to get a good design of this type of slab is necessary ensure that the stresses are properly supported, mainly those considered critical, which can lead the structure to the collapse suddenly, as is the case of punching in connection wide beam-column or of the shear in the region of the ribbed. In order to evaluate the punching strength of the slab-column connection and the shear strength of the ribs were manufactured four reinforced concrete ribbed slabs, two slabs one-way and two slabs two-way. The flexural reinforcement rate was constant in all slabs. All slabs were square of side 2200 mm and thickness equal to 150 mm. The main variable in this study was the change in height of the wide beam. This variation has to evaluate the performance of the ribs, even when the limit of spacing between them is ensured. Also, check if the punching is a possibility of rupture in this case. The estimates in this step design were based on three different standards. These were ACI 318 (2008), Eurocode 2 (2004) and NBR 6118 (ABNT, 2014). Studies with ribbed slabs have shown that the estimates of design standards are conservative. In addition, this predictions may lead to inadequate results for resistance slabs. The experimental results of this series of tests were compared to the standard recommendations in order to assess the accuracy of these three standards, which refer to the ribbed slabs. Were also built computational models in order to verify that the behavior of slabs as the stress distribution both in connection wide beam-column range as the beam connection wide beam-ribbed. The results showed that the slabs connection wide beam-ribs must be treated in a careful manner due to the difference in stiffness between the solid area and the ribs.