Navegando por Assunto "Power transformers"
Agora exibindo 1 - 3 de 3
- Resultados por página
- Opções de Ordenação
Item Acesso aberto (Open Access) Análises multifísica via método de elementos finitos para o auxílio à manutenção preditiva em transformadores de potência.(Universidade Federal do Pará, 2018-09-21) SOUSA, Antonio Roniel Marques de; NUNES, Marcus Vinícius Alves; http://lattes.cnpq.br/9533143193581447The National Interconnected System (NIS) is an organ of fundamental importance in the Brazilian panorama. Its function is to electrically connect generating centers and consumer centers, whether they are business, commercial or residential. The main equipment responsible for the connection and transmission of electric power from the generating centers to the consumers are the power transformers. This equipment is subject to several types of faults that can affect its components, in some cases compromising the operation of this equipment, and consequently the supply of electric energy. In this work, a multiphysical analysis is performed on power transformers, coupling thermal and structural electromagnetic simulations with the objective of providing the operator with information about the ideal moment for performing predictive maintenance, avoiding unplanned shutdowns. For this, computational simulations using the Finite Element Method (FEM) were used and from this, we analyzed the different situations that these equipments can be submitted, in the nominal condition, as well as extreme conditions of operation like current of inrush and current short-circuit. In this perspective, analyzes of the effects that the thermal expansion and the axial forces and radia exerted contributing to possible defects in these equipments were carried out. As a study object, the simulations were performed in a 50 MVA single-phase transformer, which is an equipment that is in operation in the northern region of the country. For a more validation of the methodology used in this work the simulations were validated with real measurement data and with results present in current literature. In this way, this work presents a methodology that can help the technical framework of an industry in the decision of the appropriate moment of stop in a power transformer for the accomplishment of predictive maintenance.Item Acesso aberto (Open Access) Detecção e localização de descargas parciais em transformadores de potência utilizando sinais acústicoas transitórios e o método GSPS(Universidade Federal do Pará, 2015-01-29) ARAÚJO, José Weliton de Oliveira; FARIAS, Rubem Gonçalves; http://lattes.cnpq.br/3261608243924147; OLIVEIRA, Rodrigo Melo e Silva de; http://lattes.cnpq.br/4768904697900863In this work, we develop a method for locating partial discharges (PDs), in power transformers, based on GPS (Global Positioning System) algorithm. For analyzing the structure, we implement a software in which the di erential equations that describe the propagation of acoustic waves are solved numerically by the Acoustic Finite-Di erence Time-Domain (AFDTD) method. The AFDTD computational domain is truncated by the CPML technique (Convolutional Perfectly Matched Layer). The obtained results are compared to estimates produced using electromagnetic waves generated by PDs.Item Acesso aberto (Open Access) Identificação de correntes de inrush na proteção diferencial de transformadores de potência através do gradiente da corrente diferencial e de mapas auto-organizáveis(Universidade Federal do Pará, 2013-06-10) ALENCAR, Raidson Jenner Negreiros de; BEZERRA, Ubiratan Holanda; http://lattes.cnpq.br/6542769654042813A principal dificuldade encontrada na proteção diferencial de transformadores de potência é a correta distinção entre as correntes de inrush e as correntes de faltas internas. Tradicionalmente os relés diferenciais executam esta tarefa utilizando a técnica de restrição por harmônicos baseada na premissa de que as correntes de inrush possuem alta concentração de componentes harmônicas de segunda ordem, contudo essa técnica nem sempre é eficaz. O presente trabalho tem como objetivo apresentar a proposta de duas novas metodologias capazes de realizar a identificação e distinção entre as correntes de inrush das correntes de faltas internas na proteção diferencial de transformadores de potência através de metodologias que não dependem do conteúdo de harmônicos do sinal da corrente diferencial. A primeira metodologia proposta, denominada de método do gradiente da corrente diferencial, é baseada no comportamento do vetor gradiente, obtido através da diferenciação numérica do sinal da corrente diferencial. O critério de distinção utilizado é baseado no desvio padrão do ângulo do vetor gradiente que apresenta comportamento diferenciado para correntes de inrush e correntes de curto-circuito. A segunda metodologia proposta é baseada na capacidade de reconhecimento e classificação de padrões das redes neurais de Mapeamento Auto-organizável de Kohonen. Como padrão de entrada e de treinamento da rede neural é utilizado um vetor contendo quatro níveis do espectro do desvio padrão do ângulo do vetor gradiente da corrente diferencial nas três fases do transformador de potência. A eficácia dos métodos foi testada através da simulação de diversas situações de faltas internas e correntes de inrush, incluindo situações de “Sympathetic Inrush”, em um transformador de potência usando o software EMTP/ATP e através da implementação do algoritmo em MATLAB®, apresentando resultados altamente promissores.