Use este identificador para citar ou linkar para este item: https://repositorio.ufpa.br/jspui/handle/2011/4092
Registro completo de metadados
Campo DCValorIdioma
dc.creatorVISANI, Valeria-
dc.creatorBARROS, Sara Regina Ribeiro Carneiro de-
dc.creatorDANTAS FILHO, Heronides Adonias-
dc.creatorALMEIDA, Luciano Farias-
dc.creatorLIMA, Ricardo Alexandre Cavalcanti de-
dc.creatorFRAGOSO, Wallace Duarte-
dc.creatorSALDANHA, Teresa Cristina Bezerra-
dc.creatorARAÚJO, Mário César Ugulino de-
dc.date.accessioned2013-08-07T16:53:31Z-
dc.date.available2013-08-07T16:53:31Z-
dc.date.issued2009-
dc.identifier.citationVISANI, Valeria, et al. Flow-batch analyser for preparation of calibration standard mixtures in simultaneous multicomponent spectrometric analysis. Eclética Química, São Paulo, v. 34, n. 2, p. 37-47, 2009. Disponível em: <http://www.scielo.br/pdf/eq/v34n2/05.pdf>. Acesso em: 18 jul. 2013. <http://dx.doi.org/10.1590/S0100-46702009000200005>.pt_BR
dc.identifier.issn1678-4618-
dc.identifier.issn0100-4670-
dc.identifier.urihttp://repositorio.ufpa.br/jspui/handle/2011/4092-
dc.description.abstractThe application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simultaneous determination of several chemical species. However, when this methodology is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high operational cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu2+, Mn2+ and Zn2+ in polyvitaminic and polymineral pharmaceutical formulations, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the preparation of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples-1 can be carried out with the proposed flow-batch analyser.pt_BR
dc.description.provenanceSubmitted by Samira Prince (prince@ufpa.br) on 2013-07-18T14:54:05Z No. of bitstreams: 2 license_rdf: 23599 bytes, checksum: 9e2b7f6edbd693264102b96ece20428a (MD5) Artigo_Flow-batchAnalyser.pdf: 504360 bytes, checksum: 100c3492e56bfe45f8250918667c200a (MD5)en
dc.description.provenanceApproved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-08-07T16:53:31Z (GMT) No. of bitstreams: 2 Artigo_Flow-batchAnalyser.pdf: 504360 bytes, checksum: 100c3492e56bfe45f8250918667c200a (MD5) license_rdf: 23599 bytes, checksum: 9e2b7f6edbd693264102b96ece20428a (MD5)en
dc.description.provenanceMade available in DSpace on 2013-08-07T16:53:31Z (GMT). No. of bitstreams: 2 Artigo_Flow-batchAnalyser.pdf: 504360 bytes, checksum: 100c3492e56bfe45f8250918667c200a (MD5) license_rdf: 23599 bytes, checksum: 9e2b7f6edbd693264102b96ece20428a (MD5) Previous issue date: 2009en
dc.language.isoengpt_BR
dc.rightsAcesso Aberto-
dc.subjectAnalisador de fluxo de lotespt_BR
dc.subjectEspectroscopia de ultravioleta e visívelpt_BR
dc.subjectAnálise multicomponente simultâneapt_BR
dc.subjectAnálise farmacêuticapt_BR
dc.titleFlow-batch analyser for preparation of calibration standard mixtures in simultaneous multicomponent spectrometric analysispt_BR
dc.typeArtigo de Periódicopt_BR
Aparece nas coleções:Artigos Científicos - FAQUI/ICEN

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Artigo_Flow-batchAnalyser.pdf492,54 kBAdobe PDFVisualizar/Abrir


Este item está licenciado sob uma Licença Creative Commons Creative Commons