Use este identificador para citar ou linkar para este item: https://repositorio.ufpa.br/jspui/handle/2011/10843
Tipo: Artigo de Periódico
Data do documento: Dez-2017
Autor(es): OLIVEIRA, Marco Antonio Barbosa de
MACÊDO, Alcebíades Negrão
POMPEU NETO, Bernardo Borges
CABRAL, Antonio Eduardo Bezerra
Afiliação do(s) Autor(es): MACÊDO, A. N.;POMPEU, B. B. Universidade Federal do Pará, Instituto de Tecnologia (ITEC)
Título: Tubos de concreto produzidos com fibras de aço e agregados da região metropolitana de Belém do Pará
Título(s) alternativo(s): Steel-fiber concrete pipes and aggregates from the metropolitan region of Belém do Pará
Citar como: OLIVEIRA, Marco Antonio Barbosa de et al. Tubos de concreto produzidos com fibras de aço e agregados da região metropolitana de Belém do Pará. Ambiente Construído, Porto Alegre,  v. 17, n. 4, p. 141-163, dez 2017. Disponível em: http://repositorio.ufpa.br/jspui/handle/2011/10843. Acesso em:.
Resumo: Os tubos de concreto com fibras de aço apresentam-se como uma variante tecnológica interessante. No estudo incipiente na localidade, o objetivo principal é o de avaliar a viabilidade técnica de tubo de concreto de armadura descontínua com fibras de aço orientadas aleatoriamente, mediante o ensaio de compressão diametral para análise do comportamento mecânico. O objetivo secundário é o de verificar a absorção de água e o teor efetivo de fibras na ponta, no meio e na bolsa do tubo. No estudo utilizaram-se as fibras de aço DRAMIX 80/60 ou 65/35, soltas ou coladas em pente, nos teores teóricos de 0,25%, 0,38% e 0,50%. Os resultados apontaram que apenas os tubos de concreto da série TCFA 80/60 - FCP nos teores efetivos de fibras de 0,36% e 0,50% e em todos os teores efetivos da série TCFA 80/60 - FS atingiram a mínima carga de ruptura e pós-fissuração estabelecida pela NBR 8890 (ABNT, 2007). Os resultados de absorção de água ficaram abaixo da máxima absorção recomendada pela NBR 8890 (ABNT, 2007) e houve maiores níveis de absorção e de teor efetivo de fibras na cadeia da ordem ponta, meio e bolsa. Ao final, mostrou-se oportuna a viabilidade técnica de tubo de concreto com fibras de aço na localidade.
Abstract: Reinforced steel-fiber concrete pipes emerge as an interesting technological variant. In an incipient study of the locality, the main objective was to assess the technical feasibility of discontinued reinforced steel-fiber concrete pipes randomly oriented by the diametrical compression test for mechanical behaviour analysis. The second objective was to verify the water absorption and effective fiber content in the spigot, barrel and bell of the tube. In this study, DRAMIX 80/60 or 65/35 steel fibers were used (loose or glued) in the theoretical contents of 0.25%, 0.38% and 0.50%. The results indicated that the concrete pipes from the TCFA 80/60 - FCP series in the effective fiber contents of 0.36% and 0.50% and the TCFA 80/60 - FS series in all effective contents were the only ones that reached the minimum failure loading and post-cracking established by the NBR 8900 (ABNT, 2007). The water absorption results were below the maximum absorption recommended by NBR 8900 (ABNT, 2007) and there were higher levels of absorption and effective fiber content in the chain from the order spigot, barrel and bell. Finally, the technical feasibility of reinforced steel-fiber concrete pipes in the locality was shown to be timely.
Palavras-chave: Concreto
Fibras de aço
Compressão diametral
Absorção
Título do Periódico: Ambiente Construído
ISSN: 1678-8621
País: Brasil
Instituição: Universidade Federal do Pará
Sigla da Instituição: UFPA
Tipo de Acesso: Acesso Aberto
Fonte URI: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-86212017000400141&lng=pt&nrm=iso
Identificador DOI: http://dx.doi.org/10.1590/s1678-86212017000400190
Aparece nas coleções:Artigos Científicos - ITEC

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Artigo_TubosConcretoProduzidos.pdf1,03 MBAdobe PDFVisualizar/Abrir


Este item está licenciado sob uma Licença Creative Commons Creative Commons