Use este identificador para citar ou linkar para este item: https://repositorio.ufpa.br/jspui/handle/2011/5960
Registro completo de metadados
Campo DCValorIdioma
dc.creatorALEIXO, Poliana Carolina-
dc.creatorNÓBREGA, Joaquim de Araújo-
dc.creatorSANTOS JÚNIOR, Dário-
dc.creatorMÜLLER, Regina Celi Sarkis-
dc.date.accessioned2014-10-31T14:04:20Z-
dc.date.available2014-10-31T14:04:20Z-
dc.date.issued2000-06-
dc.identifier.citationALEIXO, Poliana C. et al. Determinação direta de selênio em água de coco e em leite de coco utilizando espectrometria de absorção atômica com atomização eletrotérmica em forno de grafite. Química Nova, São Paulo, v. 23, n. 3, p. 310-312, maio/jun. 2000. Disponível em: <http://www.scielo.br/pdf/qn/v23n3/2814.pdf>. Acesso em: 23 jul. 2014. <http://dx.doi.org/10.1590/S0100-40422000000300005>.pt_BR
dc.identifier.issn0100-4042-
dc.identifier.urihttp://repositorio.ufpa.br/jspui/handle/2011/5960-
dc.description.abstractSelenium is both essential and toxic to man and animals, depending on the concentration and the ingested form. Most fruits and vegetables are poor sources of selenium, but coconut can be a good selenium source. Samples were suspended (1 + 4 v/v) in a mixture of tertiary amines soluble in water (10% v/v CFA-C). This simple sample treatment avoided contamination and decreased the analysis time. The standard additions method was adopted for quantification. The action of the autosampler was improved by the presence of the amines mixture in the suspension. A Varian model AA-800 atomic absorption spectrometer equipped with a graphite furnace and a GTA 100 autosampler was used for selenium determination in coconut water and coconut milk. Background correction was performed by means of the Zeeman effect. Pyrolytically coated graphite tubes were employed. Using Pd as chemical modifier, the pyrolysis and the atomization temperatures were set at 1400 and 2200oC, respectively. For six samples, the selenium concentration in coconut water varied from 6.5 to 21.0 mg L-1 and in coconut milk from 24.2 to 25.1 mg L-1. The accuracy of the proposed method was evaluated by an addition-recovery experiment and all recovered values are in the 99.5-102.3% range. The main advantage of the proposed method is that it can be directly applied without sample decomposition.pt_BR
dc.description.provenanceSubmitted by Edisangela Bastos (edisangela@ufpa.br) on 2014-10-23T22:24:59Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Artigo_DeterminacaoDiretaSelenio.pdf: 29144 bytes, checksum: 2eddbddea6e033b91983b32706c83625 (MD5)en
dc.description.provenanceApproved for entry into archive by Albirene Aires (albireneufpa@gmail.com) on 2014-10-31T14:04:20Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Artigo_DeterminacaoDiretaSelenio.pdf: 29144 bytes, checksum: 2eddbddea6e033b91983b32706c83625 (MD5)en
dc.description.provenanceMade available in DSpace on 2014-10-31T14:04:20Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Artigo_DeterminacaoDiretaSelenio.pdf: 29144 bytes, checksum: 2eddbddea6e033b91983b32706c83625 (MD5) Previous issue date: 2000-06en
dc.language.isoporpt_BR
dc.rightsAcesso Aberto-
dc.subjectSelêniopt_BR
dc.subjectÁgua de cocopt_BR
dc.subjectLeite de cocopt_BR
dc.subjectComposição mineralpt_BR
dc.subjectEspectrometria de absorção atômica em forno de grafitept_BR
dc.titleDeterminação direta de selênio em água de coco e em leite de coco utilizando espectrometria de absorção atômica com atomização eletrotérmica em forno de grafitept_BR
dc.title.alternativeDirect determination of selenium in coconut water and coconut milk using graphite furnace atomic absorption spectrometrypt_BR
dc.typeArtigo de Periódicopt_BR
Aparece nas coleções:Artigos Científicos - FAQUI/ICEN

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Artigo_DeterminacaoDiretaSelenio.pdf28,46 kBAdobe PDFVisualizar/Abrir


Este item está licenciado sob uma Licença Creative Commons Creative Commons