Use este identificador para citar ou linkar para este item: https://repositorio.ufpa.br/jspui/handle/2011/6643
Registro completo de metadados
Campo DCValorIdioma
dc.creatorLIRA, Ana de Lourdes Sá de-
dc.creatorPRADO, Sávio Raimundo Lemos-
dc.creatorARAÚJO, Mônica Tirre-
dc.creatorSANT'ANNA, Eduardo Franzotti-
dc.creatorRUELLAS, Antonio Carlos de Oliveira-
dc.date.accessioned2015-05-11T13:57:23Z-
dc.date.available2015-05-11T13:57:23Z-
dc.date.issued2013-04-
dc.identifier.citationLIRA, Ana de Lourdes Sá de et al. Distal movement of upper permanent molars using midpalatal mini-implant. Dental Press Journal of Orthodontics, Maringá, v. 18, n. 2, p. 18e1-18e5, mar./abr. 2013. Disponível em: <http://www.scielo.br/pdf/dpjo/v18n2/a06v18n2.pdf>. Acesso em: 07 maio 2015. <http://dx.doi.org/10.1590/S2176-94512013000200006>.pt_BR
dc.identifier.issn2176-9451-
dc.identifier.urihttp://repositorio.ufpa.br/jspui/handle/2011/6643-
dc.description.abstractOBJECTIVE: To assess whether palatal mini-implants are effective as direct anchorage for distal movement of the upper molars. METHODS: It was used an acrylic model of the upper dental arch. After making a groove in the region corresponding to dental alveolus, acrylic teeth were fixed in groove with #7 wax, with the roots being previously immersed in adhesive wax. The orthodontic appliance was placed according to the Edgewise technique and then a mini-implant (SIN, São Paulo, Brazil) was inserted at the site corresponding to the palatal raphe. A 0.019 x 0.025-in stainless steel archwire was made and attached to the upper arch with elastics. A transpalatal arch bar (0.019 x 0.025in) was mounted and two hooks were soldered to it in order to retain chain elastics (Unitek, Brazil) to be connected to the mini-implant under a force of 1.5 N on each side. The maxillary model was immersed in water 40 times and photographed after each immersion, for observation of dental movements. Analysis of variance (ANOVA) and Tukey's test were employed for analyzing the obtained data. RESULTS: Molars displaced distally 3.1 mm, in average, with distal inclination ranging from 3 to 5 mm. CONCLUSIONS: Molar movements occurred due to distal inclination, with a slight rotation and no extrusive effect.pt_BR
dc.description.provenanceSubmitted by Edisangela Bastos (edisangela@ufpa.br) on 2015-05-07T18:16:40Z No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) Artigo_DistalMovementUpper.pdf: 163234 bytes, checksum: cfa27ceb6d230d46bc8d853f02e7aebd (MD5)en
dc.description.provenanceApproved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2015-05-11T13:57:23Z (GMT) No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) Artigo_DistalMovementUpper.pdf: 163234 bytes, checksum: cfa27ceb6d230d46bc8d853f02e7aebd (MD5)en
dc.description.provenanceMade available in DSpace on 2015-05-11T13:57:23Z (GMT). No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) Artigo_DistalMovementUpper.pdf: 163234 bytes, checksum: cfa27ceb6d230d46bc8d853f02e7aebd (MD5) Previous issue date: 2013-04en
dc.language.isoengpt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectOrtodontiapt_BR
dc.subjectMovimentação dentáriapt_BR
dc.subjectProcedimentos de ancoragem ortodônticaspt_BR
dc.subjectPalato duropt_BR
dc.titleDistal movement of upper permanent molars using midpalatal mini-implantpt_BR
dc.typeArtigo de Periódicopt_BR
dc.description.resumoOBJETIVO: verificar se o mini-implante no palato é eficaz como ancoragem direta para distalização dos molares superiores. MÉTODOS: foi utilizado um modelo em acrílico da arcada superior. Após a confecção da canaleta na região correspondente aos alvéolos dentários, os dentes em acrílico foram fixados com cera #7, montado aparelho ortodôntico com a técnica Edgewise e inserido um mini-implante (SIN, São Paulo) no local correspondente à rafe palatina. Foram colocados arco 0,19" x 0,25" e barra transpalatina, soldados na barra dois ganchos para retenção de dois elásticos em cadeia de dois elos, a uma carga de 150g/f de cada lado (Unitek), que se estenderam dos ganchos até o mini-implante. O modelo da maxila foi mergulhado 40 vezes em banheira e fotografado após cada mergulho para observação da movimentação dentária. Os dados foram analisados pela análise da variânçia (ANOVA) e teste de Tukey. RESULTADOS: os molares deslocaram-se distalmente 3,1mm, em média, com inclinação distal entre 3 e 5mm. CONCLUÕES: a movimentação dos molares ocorreu pela inclinação distal, com leve rotação, mas sem efeito extrusivo.pt_BR
Aparece nas coleções:Artigos Científicos - FOUFPA/ICS

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Artigo_DistalMovementUpper.pdf159,41 kBAdobe PDFVisualizar/Abrir


Este item está licenciado sob uma Licença Creative Commons Creative Commons