Please use this identifier to cite or link to this item: https://repositorio.ufpa.br/jspui/handle/2011/8167
metadata.dc.type: Artigo de Periódico
Issue Date: Oct-2012
metadata.dc.creator: SACRAMENTO, Paulo Victor Prazeres
FERREIRA, Maurício de Pina
OLIVEIRA, Dênio Ramam Carvalho de
MELO, Guilherme Sales Soares de Azevedo
Title: Punching strength of reinforced concrete flat slabs without shear reinforcement
Other Titles: Punção em lajes lisas de concreto armado sem armadura de cisalhamento
Citation: SACRAMENTO, Paulo Víctor Prazeres et al. Punching strength of reinforced concrete flat slabs without shear reinforcement. Revista Ibracon de Estruturas e Materiais, São Paulo, v. 5, n. 5, p. 659-691, out. 2012. Disponível em: <http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952012000500005&lng=pt&nrm=iso> ; <http://www.scielo.br/pdf/riem/v5n5/pt_a05v5n5.pdf>. Acesso em: 12 abr. 2017. <http://dx.doi.org/10.1590/S1983-41952012000500005>.
metadata.dc.description.resumo: O dimensionamento à punção é um ponto crítico no projeto de lajes lisas e devido à falta de um método teórico capaz de explicar este fenômeno a verificação da capacidade resistente de ligações laje-pilar é feita normalmente utilizando-se as recomendações de normas de projeto. Este artigo discute aspectos relevantes do surgimento do sistema de lajes lisas, dos fatores que influenciam na resistência à punção de lajes sem armadura de cisalhamento e faz comparações entre os resultados experimentais de um banco de dados com 74 lajes cuidadosamente selecionadas com resultados teóricos utilizando-se as recomendações das normas ACI 318, EUROCODE 2 e NBR 6118 e também através da Teoria da Fissura Crítica de Cisalhamento, apresentada por Muttoni (2008) e incorporada à nova norma fib Model Code (2010).
Abstract: Punching strength is a critical point in the design of flat slabs and due to the lack of a theoretical method capable of explaining this phenomenon, empirical formulations presented by codes of practice are still the most used method to check the bearing capacity of slab-column connections. This paper discusses relevant aspects of the development of flat slabs, the factors that influence the punching resistance of slabs without shear reinforcement and makes comparisons between the experimental results organized in a database with 74 slabs carefully selected with theoretical results using the recommendations of ACI 318, EUROCODE 2 and NBR 6118 and also through the Critical Shear Crack Theory, presented by Muttoni (2008) and incorporated the new fib Model Code (2010).
Keywords: Lajes lisas
Punção
Concreto armado
Normas técnicas (Engenharia)
Resistência de materiais
Fissura
Cisalhamento
Series/Report no.: Revista IBRACON de Estruturas e Materiais
ISSN: 1983-4195
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal do Pará
metadata.dc.publisher.initials: UFPA
metadata.dc.rights: Acesso Aberto
Appears in Collections:Artigos Científicos - FEC/ITEC

Files in This Item:
File Description SizeFormat 
Artigo_PunchingStrengthReinforced.pdfINGLÊS4,18 MBAdobe PDFView/Open
Artigo_PuncaoLajesLisas.pdfPORTUGUÊS4,23 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons