2017-04-122017-04-122012-10SACRAMENTO, Paulo Víctor Prazeres et al. Punching strength of reinforced concrete flat slabs without shear reinforcement. Revista Ibracon de Estruturas e Materiais, São Paulo, v. 5, n. 5, p. 659-691, out. 2012. Disponível em: <http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952012000500005&lng=pt&nrm=iso> ; <http://www.scielo.br/pdf/riem/v5n5/pt_a05v5n5.pdf>. Acesso em: 12 abr. 2017. <http://dx.doi.org/10.1590/S1983-41952012000500005>.1983-4195https://repositorio.ufpa.br/handle/2011/8167Punching strength is a critical point in the design of flat slabs and due to the lack of a theoretical method capable of explaining this phenomenon, empirical formulations presented by codes of practice are still the most used method to check the bearing capacity of slab-column connections. This paper discusses relevant aspects of the development of flat slabs, the factors that influence the punching resistance of slabs without shear reinforcement and makes comparisons between the experimental results organized in a database with 74 slabs carefully selected with theoretical results using the recommendations of ACI 318, EUROCODE 2 and NBR 6118 and also through the Critical Shear Crack Theory, presented by Muttoni (2008) and incorporated the new fib Model Code (2010).Acesso AbertoLajes lisasPunçãoConcreto armadoNormas técnicas (Engenharia)Resistência de materiaisFissuraCisalhamentoPunching strength of reinforced concrete flat slabs without shear reinforcementPunção em lajes lisas de concreto armado sem armadura de cisalhamentoArtigo de Periódico