Faculdade de Engenharia Civil - FEC/ITEC
URI Permanente desta comunidadehttps://repositorio.ufpa.br/handle/2011/2788
Navegar
Navegando Faculdade de Engenharia Civil - FEC/ITEC por Autor "FERREIRA, Maurício de Pina"
Agora exibindo 1 - 7 de 7
- Resultados por página
- Opções de Ordenação
Item Acesso aberto (Open Access) Contribuição ao estudo de lajes lisas unidirecionais de concreto armado com pilares retangulares ao puncionamento(2007-12) FERREIRA, Maurício de Pina; OLIVEIRA, Dênio Ramam Carvalho deAnalysis of recommendations to predict the ultimate punching resistance of flat slabs according to the actual Brazilian code, NBR 6118:2003, which does not consider the effects of the internal columns' rectangularity, and its previous version, NBR 6118:1980, are presented. In rectangular cross sections, the shear stress polarization rate is crescent. Thus, the slab failure mode changes, since the punching failure takes place at the column's ends, without compromizing the larger sides, as recommended by the new version of the code. This behavior tends to reduce the ultimate punching resistance of flat slabs when the normative estimates are compared. In addition to the results from the two codes, are presented a numerical analysis by the Finite Element Method and a proposal to improve the ductility of flat slabs based on the minimal dimensions for rectangular columns. The results showed that the NBR 6118:2003 estimates can be improved.Item Acesso aberto (Open Access) Influence of the column rectangularity index and of the boundary conditions in the punching resistance of slab-column connections(Universidade Federal do Pará, 2015-06) PAIVA, Odilson da Silva de; FERREIRA, Maurício de Pina; OLIVEIRA, Dênio Ramam Carvalho de; LIMA NETO, Aarão Ferreira; TEIXEIRA, Marcelo RassyExperimental evidence indicates that both the column rectangularity index and the boundary conditions of the connection may affect the ultimate punching resistance. This paper presents general aspects of these topics and, through the analysis of experimental results of tests on 131 slabs, evaluates the accuracy and suitability of recommendations presented by ABNT NBR 6118, Eurocode 2, ACI 318 and fib Model Code 2010. Experimental results showed that the security level of normative estimates trend to reduce as the column rectangularity increases, and in some cases, the punching resistance was overestimated. Finally, adjustments are suggested in equations presented by NBR 6118 and MC2010 in order to eliminate this trend of unsafe results.Item Acesso aberto (Open Access) Lajes lisas nervuradas bidirecionais com furos(Universidade Federal do Pará, 2014-08) MATEUS, Gustavo Menezes; AGUIAR, Amaury José Oliveira de; FERREIRA, Maurício de Pina; OLIVEIRA, Dênio Ramam Carvalho deThe position of pipes and hoses for several installations still deserves special attention from designers mainly when the failure mode can be modified due to changes in behavior. This work compares experimental results of six two-way reinforced concrete ribbed flat slabs with rectangular holes close to the column and without shear reinforcement with the estimates obtained from codes ACI 318 and NBR 6118 equations. All slabs were casted and tested in the Civil Engineering Laboratory of UFPA and had dimensions of 1.800 mm x 1.800 mm x 150 mm and were submitted to central loading applied through 120 mm side square steel plates simulating the columns. EPS was used as inert material and the ribs were spaced 250 mm with 130 mm height and 75 mm average wide. The results showed that the codes’ shear equations estimates agree when the ribs are considered as beam and also for punching shear, but trend to be safer when the slabs present two shafts.Item Acesso aberto (Open Access) Punching resistance of internal slab-column connections with double-headed shear studs(Universidade Federal do Pará, 2013-10) OLIVEIRA, Marcos Honorato de; PEREIRA FILHO, Manoel José Mangabeira; OLIVEIRA, Dênio Ramam Carvalho de; FERREIRA, Maurício de Pina; MELO, Guilherme Sales Soares de AzevedoPunching shear is a brittle failure mode that may occur in slab-column connections, which may be prevented by using shear reinforcement in the slab-column connection. This paper presents comparisons between experimental results of 36 tests in internal slab-column connections with double- headed shear studs, which are largely used in North America, Europe and Asia, with theoretical results using recommendations presented by ACI 318, NBR6118, Eurocode 2 and also the Critical Shear Crack Theory (CSCT).Considering the database used it is possible to observe that ACI 318 presents conservative trends, whereas NBR 6118 showed a low coefficient of variation, but with a large number of unsafe results. Both Eurocode 2 and CSCT showed satisfactory results with Eurocode 2 presenting slightly higher performance.Item Acesso aberto (Open Access) Punching shear resistance of reinforced concrete footings: evaluation of design codes(Universidade Federal do Pará, 2018-04) SANTOS, Douglas Freitas Augusto dos; LIMA NETO, Aarão Ferreira; FERREIRA, Maurício de PinaPunching is a possible failure mode for slender footings and it may lead a structure to ruin through progressive collapse. Although footing present different geometric characteristics, their punching shear design is based on the empirical methods used for flat slabs. This paper uses experimental results from 216 tests to evaluate the performance of design code recommendations presented by ACI 318 (2014), ABNT NBR 6118 (2014) and Eurocode 2 (2010) to estimate the punching shear resistance of reinforced concrete footings. Great dispersion between theoretical and experimental results was observed, being evident that the test system affects the punching shear capacity of footings. The more complex method proposed by Eurocode 2 resulted in a better correlation with experimental results.Item Acesso aberto (Open Access) Punching strength of reinforced concrete flat slabs without shear reinforcement(Universidade Federal do Pará, 2012-10) SACRAMENTO, Paulo Victor Prazeres; FERREIRA, Maurício de Pina; OLIVEIRA, Dênio Ramam Carvalho de; MELO, Guilherme Sales Soares de AzevedoPunching strength is a critical point in the design of flat slabs and due to the lack of a theoretical method capable of explaining this phenomenon, empirical formulations presented by codes of practice are still the most used method to check the bearing capacity of slab-column connections. This paper discusses relevant aspects of the development of flat slabs, the factors that influence the punching resistance of slabs without shear reinforcement and makes comparisons between the experimental results organized in a database with 74 slabs carefully selected with theoretical results using the recommendations of ACI 318, EUROCODE 2 and NBR 6118 and also through the Critical Shear Crack Theory, presented by Muttoni (2008) and incorporated the new fib Model Code (2010).Item Acesso aberto (Open Access) Resistência ao cisalhamento de lajes nervuradas unidirecionais de concreto armado(Universidade Federal do Pará, 2014-08) SOUZA, Wallace Maia de; CAETANO, Thiago Rodrigues Gonçalves; FERREIRA, Maurício de Pina; OLIVEIRA, Dênio Ramam Carvalho deThe shear strength of one-way reinforced concrete ribbed slabs without stirrups in the ribs is still controversial when its estimate does not consider the contribution of the monolithic flange. To contribute to a better understanding of the behavior of these slabs were fabricated in the laboratory 8 one-way reinforced concrete ribbed slab panels where the main variables were the distance between the ribs and the thickness of the flange. The normative recommendations of NBR 6118, ACI 318 and EUROCODE 2 for the ultimate resistance of these slabs were evaluated. The experimental results showed an increase of shear strength with increasing thickness of the flange, also resulting in greater reinforcement strains and higher deflections.