Título: | Cyclic fatigue resistance of rotary niti instruments after simulated clinical use in curved root canals |
Citar como: | PESSOA, Oscar Faciola; SILVA, Juliana Melo da; GAVINI, Giulio. Cyclic fatigue resistance of rotary niti instruments after simulated clinical use in curved root canals. Brazilian Dental Journal, Ribeirão Preto, v. 24, n. 2, p. 117-120, abr. 2013. Disponível em: <http://www.scielo.br/pdf/bdj/v24n2/0103-6440-bdj-24-02-117.pdf>. Acesso em: 22 abr. 2015. <http://dx.doi.org/10.1590/0103-6440201302164>. |
Resumo: | O objetivo deste estudo foi avaliar a resistência à fadiga cíclica de instrumentos rotatórios de níquel-titânio após simulação de uso clinico em canais curvos (curvatura de 40° e raio de 5 mm). Trinta e seis instrumentos, calibre n° 25 conicidade 0,04, foram divididos em três grupos: o Grupo A com um ciclo de uso; Grupo B, três ciclos de uso e grupo C, cinco ciclos de uso. Um cronômetro digital aferiu em segundos o tempo até a fratura do instrumento que, posteriormente, foi convertido em número de ciclos para fratura. Os dados foram analisados por ANOVA e teste de Tukey (p<0,05). O grupo que utilizou o instrumento por cinco ciclos (grupo C) atingiu significativamente menores números de ciclos antes da fratura (média = 197,5 ciclos) quando comparado com os instrumentos utilizados em um ciclo (média = 309,2) e três ciclos (média = 287,5). Os resultados mostraram que o número de uso de instrumentos RaCe para modelar canais curvos afeta negativamente a resistência à fadiga cíclica dos instrumentos após cinco usos. |
Abstract: | The aim of this study was to assess cyclic fatigue resistance in rotary nickel-titanium instruments after simulated clinical use in curved root canals (40-degree, 5-mm radius curve). Thirty-six RaCe rotary NiTi files, size #5, taper 0.04, were divided into 3 groups: Groups A, B and C with one, three and five cycles of use, respectively. Time to failure was recorded with a stopwatch in seconds and subsequently converted to number of cycles to fracture. The data were analyzed statistically by ANOVA and Tukey's test (α=0.05). Five sets of clinically used files (group C) reached significantly lower cycle-numbers before fracture (mean=197.5 cycles) when compared with one set of clinically used files (mean=309.2) and three sets (mean=287.5). Results showed that the number of simulated clinical uses of RaCe instruments for shaping curved canals affects adversely the fatigue resistance of these instruments after five uses. |
Palavras-chave: | Entodontia Fadiga cíclica Níquel-titânio Cavidade pulpar Instrumentos odontológicos Instrumentos rotatórios |
ISSN: | 0103-6440 |
Tipo de Acesso: | Acesso Aberto |
Aparece nas coleções: | Artigos Científicos - FOUFPA/ICS |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Artigo_CyclicFatigueResistance.pdf | 364,37 kB | Adobe PDF | Visualizar/Abrir |
Este item está licenciado sob uma Licença Creative Commons