Use este identificador para citar ou linkar para este item:
https://repositorio.ufpa.br/jspui/handle/2011/10240
Tipo: | Artigo de Periódico |
Data do documento: | Out-2013 |
Autor(es): | OLIVEIRA, Marcos Honorato de PEREIRA FILHO, Manoel José Mangabeira OLIVEIRA, Dênio Ramam Carvalho de FERREIRA, Maurício de Pina MELO, Guilherme Sales Soares de Azevedo |
Afiliação do(s) Autor(es): | OLIVEIRA, D. R. C. Pós-Dr. Docente da Universidade Federal do Pará, Instituto de Tecnologia, Faculdade de Engenharia Civil FERREIRA, M. P. Pós-Dr. Docente da Universidade Federal do Pará, Instituto de Tecnologia, Faculdade de Engenharia Civil |
Título: | Punching resistance of internal slab-column connections with double-headed shear studs |
Título(s) alternativo(s): | Resistência à punção de ligações laje-pilar interno com conectores de cisalhamento |
Citar como: | OLIVEIRA, M. H. et al. Punching resistance of internal slab-column connections with double-headed shear studs. Revista Ibracon de Estruturas e Materiais, São Paulo, v. 6, n. 5, p. 698-714, out. 2013. Disponível em: <http://repositorio.ufpa.br/jspui/handle/2011/10240>. Acesso em:. |
Resumo: | A punção é uma forma de ruptura por cisalhamento que pode ocorrer em ligações laje-pilar que pode ser evitada utilizando-se armaduras de cisalhamento na ligação. Este artigo apresenta comparações entre resultados experimentais de 36 ensaios realizados em ligações laje-pilar interno, armadas com conectores de cisalhamento do tipo pino de duas cabeças, populares na América do Norte, Europa e Ásia, com resultados teóricos utilizando as recomendações do ACI 318, NBR 6118, Eurocode 2, além da Teoria da Fissura Crítica de Cisalhamento (TFCC). Para o banco de dados utilizado, o ACI 318 mostrou tendências conservadoras, enquanto que a NBR 6118 mostrou baixo coeficiente de variação, mas um grande número de resultados contra a segurança. Tanto o Eurocode 2, quanto a TFCC apresentaram resultados satisfatórios, com o Eurocode 2 apresentando desempenho ligeiramente superior. |
Abstract: | Punching shear is a brittle failure mode that may occur in slab-column connections, which may be prevented by using shear reinforcement in the slab-column connection. This paper presents comparisons between experimental results of 36 tests in internal slab-column connections with double- headed shear studs, which are largely used in North America, Europe and Asia, with theoretical results using recommendations presented by ACI 318, NBR6118, Eurocode 2 and also the Critical Shear Crack Theory (CSCT).Considering the database used it is possible to observe that ACI 318 presents conservative trends, whereas NBR 6118 showed a low coefficient of variation, but with a large number of unsafe results. Both Eurocode 2 and CSCT showed satisfactory results with Eurocode 2 presenting slightly higher performance. |
Palavras-chave: | Lajes lisas Punção Conectores de cisalhamento Armadura de cisalhamento |
CNPq: | CNPQ::ENGENHARIAS::ENGENHARIA CIVIL |
Título do Periódico: | Revista IBRACON de Estruturas e Materiais |
ISSN: | 1983-4195 |
País: | Brasil |
Instituição: | Universidade Federal do Pará |
Sigla da Instituição: | UFPA |
Tipo de Acesso: | Acesso Aberto |
Fonte URI: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952013000500002&lng=pt&nrm=iso |
Identificador DOI: | http://dx.doi.org/10.1590/S1983-41952013000500002 |
Aparece nas coleções: | Artigos Científicos - FEC/ITEC |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Article_PunchingResistanceInternal.pdf | INGLÊS | 2,8 MB | Adobe PDF | Visualizar/Abrir |
Artigo_ResistenciaPuncaoLigacoes.pdf | PORTUGUÊS | 2,79 MB | Adobe PDF | Visualizar/Abrir |
Este item está licenciado sob uma Licença Creative Commons