Title: Punching resistance of internal slab-column connections with double-headed shear studs
Other Titles: Resistência à punção de ligações laje-pilar interno com conectores de cisalhamento
Citation: OLIVEIRA, M. H. et al. Punching resistance of internal slab-column connections with double-headed shear studs. Revista Ibracon de Estruturas e Materiais, São Paulo, v. 6, n. 5, p. 698-714, out. 2013. Disponível em: <http://repositorio.ufpa.br/jspui/handle/2011/10240>. Acesso em:.
metadata.dc.description.resumo: A punção é uma forma de ruptura por cisalhamento que pode ocorrer em ligações laje-pilar que pode ser evitada utilizando-se armaduras de cisalhamento na ligação. Este artigo apresenta comparações entre resultados experimentais de 36 ensaios realizados em ligações laje-pilar interno, armadas com conectores de cisalhamento do tipo pino de duas cabeças, populares na América do Norte, Europa e Ásia, com resultados teóricos utilizando as recomendações do ACI 318, NBR 6118, Eurocode 2, além da Teoria da Fissura Crítica de Cisalhamento (TFCC). Para o banco de dados utilizado, o ACI 318 mostrou tendências conservadoras, enquanto que a NBR 6118 mostrou baixo coeficiente de variação, mas um grande número de resultados contra a segurança. Tanto o Eurocode 2, quanto a TFCC apresentaram resultados satisfatórios, com o Eurocode 2 apresentando desempenho ligeiramente superior.
Abstract: Punching shear is a brittle failure mode that may occur in slab-column connections, which may be prevented by using shear reinforcement in the slab-column connection. This paper presents comparisons between experimental results of 36 tests in internal slab-column connections with double- headed shear studs, which are largely used in North America, Europe and Asia, with theoretical results using recommendations presented by ACI 318, NBR6118, Eurocode 2 and also the Critical Shear Crack Theory (CSCT).Considering the database used it is possible to observe that ACI 318 presents conservative trends, whereas NBR 6118 showed a low coefficient of variation, but with a large number of unsafe results. Both Eurocode 2 and CSCT showed satisfactory results with Eurocode 2 presenting slightly higher performance.
Keywords: Lajes lisas
Punção
Conectores de cisalhamento
Armadura de cisalhamento
metadata.dc.subject.cnpq: CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
Series/Report no.: Revista IBRACON de Estruturas e Materiais
ISSN: 1983-4195
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal do Pará
metadata.dc.publisher.initials: UFPA
metadata.dc.rights: Acesso Aberto
metadata.dc.source.uri: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952013000500002&lng=pt&nrm=iso
metadata.dc.identifier.doi: http://dx.doi.org/10.1590/S1983-41952013000500002
Appears in Collections:Artigos Científicos - FEC/ITEC

Files in This Item:
File Description SizeFormat 
Article_PunchingResistanceInternal.pdfINGLÊS2,8 MBAdobe PDFView/Open
Artigo_ResistenciaPuncaoLigacoes.pdfPORTUGUÊS2,79 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons