Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.ufpa.br/jspui/handle/2011/10255
Tipo: Artigo de Periódico
Fecha de publicación : oct-2011
Autor(es): SOUZA, Shirley do Socorro Melo de
OLIVEIRA, Dênio Ramam Carvalho de
metadata.dc.description.affiliation: OLIVEIRA, D. R. C. Pós-Dr. Docente da Universidade Federal do Pará, Instituto de Tecnologia, Faculdade de Engenharia Civil
Título : Lajes lisas nervuradas de concreto armado ao cisalhamento
Otros títulos : Reinforced concrete waffle flat slabs under shearing
Citación : SOUZA, S. S. M.; OLIVEIRA, D. R. C.. Lajes lisas nervuradas de concreto armado ao cisalhamento. Revista Ibracon de Estrutura e Materiais, São Paulo, v. 4, n. 4, p. 627-641, out. 2011. Disponível em: <http://repositorio.ufpa.br/jspui/handle/2011/10255>. Acesso em:.
Resumen: Os sistemas estruturais com lajes lisas nervuradas são os mais utilizados no Brasil quando a exigência principal é a disponibilidade de "layouts" flexíveis e grandes vãos com razoável economia. Entretanto, poucos estudos foram realizados no Brasil considerando o comportamento destas lajes quando a resistência à flexão é satisfatória e as resistências ao cisalhamento nas nervuras e ao puncionamento tornam-se concorrentes. Este trabalho traz as análises experimentais de 8 lajes lisas nervuradas bidirecionais de concreto armado sujeitas a carregamento centrado. As dimensões das lajes foram constantes e iguais a 1.800 mm x 1.800 mm x 140 mm. As nervuras apresentaram 80 mm de altura por 50 mm de base e a resistência do concreto à compressão foi de aproximadamente 40 MPa. Os resultados foram comparados aos estimados pela norma brasileira NBR 6118:2003 1. Verificou-se que a resistência das nervuras não é satisfatoriamente estimada pela norma, subestimando demasiadamente os resultados para as nervuras sem e com armadura de cisalhamento.
Resumen : The structural systems with waffle flat slabs are the most used in Brazil when the main requirement is flexible "layouts" and long spans with reasonable economy. However, few studies have been developed in Brazil regarding the behavior of these slabs when the flexural resistance is satisfactory and the shear in the ribs and punching resistances become competitive. This work shows the experimental analysis of 8 two-way reinforced concrete waffle flat slabs under centered load. The dimensions of the slabs were the same and equal to 1800 mm x 1800 mm x 140 mm. The ribs were 80 mm (height) by 50 mm (width) and the compressive concrete strength was approximately 40 MPa. The experimental results were compared to those estimated by the Brazilian code NBR 6118:2003. It was verified that the resistance of the ribs is not satisfactorily estimated by the code, which excessively underestimates the results for ribs with and without shear reinforcement.
Palabras clave : Concreto armado
Laje nervurada
Laje lisa
Cisalhamento
Punção
CNPq: CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
Series/Report no.: Revista IBRACON de Estruturas e Materiais
ISSN : 1983-4195
País: Brasil
Editorial : Universidade Federal do Pará
Sigla da Instituição: UFPA
metadata.dc.rights: Acesso Aberto
metadata.dc.source.uri: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952011000400007&lng=pt&nrm=iso
metadata.dc.identifier.doi: http://dx.doi.org/10.1590/S1983-41952011000400007
Aparece en las colecciones: Artigos Científicos - FEC/ITEC

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Artigo_LagesLisasNervuradas.pdfPORTUGUUÊS4,57 MBAdobe PDFVisualizar/Abrir
Article_ReinforcedConcreteWaffle.pdfINGLÊS4,41 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons