Please use this identifier to cite or link to this item: https://repositorio.ufpa.br/jspui/handle/2011/8158
metadata.dc.type: Artigo de Periódico
Issue Date: Aug-2014
metadata.dc.creator: MATEUS, Gustavo Menezes
AGUIAR, Amaury José Oliveira de
FERREIRA, Maurício de Pina
OLIVEIRA, Dênio Ramam Carvalho de
Title: Lajes lisas nervuradas bidirecionais com furos
Other Titles: Two-way ribbed flat slabs with shafts
Citation: MATEUS, Gustavo Menezes et al. Lajes lisas nervuradas bidirecionais com furos. Revista Ibracon de Estrutruturas e Materiais, São Paulo, v. 7, n. 4, p. 572-591, ago. 2014. Disponível em: <http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952014000400004&lng=pt&nrm=iso> ; <http://www.scielo.br/pdf/riem/v7n4/en_04.pdf>. Acesso em: 12 abr. 2017. <http://dx.doi.org/10.1590/S1983-41952014000400004>.
metadata.dc.description.resumo: A passagem de tubulações em elementos estruturais ainda merece atenção especial dos projetistas, principalmente quando o modo de ruptura dos mesmos pode ser alterado devido às mudanças em seus comportamentos. Este trabalho compara os resultados experimentais obtidos para 06 (seis) lajes lisas nervuradas bidirecionais em concreto armado, com furos retangulares adjacentes aos pilares e sem armadura de cisalhamento, com as estimativas das formulações dadas pelas normas ACI 318 e NBR 6118. As lajes foram moldadas e ensaiadas no Laboratório de Engenharia Civil da UFPA e apresentaram dimensões de 1.800 mm x 1.800 mm x 150 mm, sendo submetidas a carregamento central em placas quadradas que simularam pilares com 120 mm de lado. O material inerte entre as nervuras foi o EPS e o espaçamento entre as mesmas foi de 250 mm, com largura média de 75 mm e altura 130 mm. Os resultados mostraram que as normas convergem em suas estimativas de resistência ao cisalhamento, quando as nervuras são tratadas isoladamente como vigas, e também ao puncionamento, mas neste caso tendem a ser conservadoras quando as lajes apresentam dois furos.
Abstract: The position of pipes and hoses for several installations still deserves special attention from designers mainly when the failure mode can be modified due to changes in behavior. This work compares experimental results of six two-way reinforced concrete ribbed flat slabs with rectangular holes close to the column and without shear reinforcement with the estimates obtained from codes ACI 318 and NBR 6118 equations. All slabs were casted and tested in the Civil Engineering Laboratory of UFPA and had dimensions of 1.800 mm x 1.800 mm x 150 mm and were submitted to central loading applied through 120 mm side square steel plates simulating the columns. EPS was used as inert material and the ribs were spaced 250 mm with 130 mm height and 75 mm average wide. The results showed that the codes’ shear equations estimates agree when the ribs are considered as beam and also for punching shear, but trend to be safer when the slabs present two shafts.
Keywords: Resistência ao cisalhamento
Resistência de materiais
Fissura
Punção
Laje lisa
Laje nervurada
Normas técnicas (Engenharia)
Series/Report no.: Revista IBRACON de Estruturas e Materiais
ISSN: 1983-4195
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal do Pará
metadata.dc.publisher.initials: UFPA
metadata.dc.rights: Acesso Aberto
Appears in Collections:Artigos Científicos - FEC/ITEC

Files in This Item:
File Description SizeFormat 
Artigo_LajesLisasNervuradas.pdfPORTUGUÊS2,28 MBAdobe PDFView/Open
Artigo_TwoWayRibbed.pdfINGLÊS7 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons