Use este identificador para citar ou linkar para este item: https://repositorio.ufpa.br/jspui/handle/2011/9238
Tipo: Dissertação
Data do documento: 18-Ago-2014
Autor(es): MODESTO, Jonathas Felippe Morais
Primeiro(a) Orientador(a): OLIVEIRA, Rodrigo Melo e Silva de
Primeiro(a) coorientador(a): DMITRIEV, Victor
Título: Método espectral para localização de múltiplas descargas parciais na parte dielétrica de bobinas de hidrogeradores
Agência de fomento: 
Citar como: MODESTO, Jonathas Felippe Morais. Método espectral para localização de múltiplas descargas parciais na parte dielétrica de bobinas de hidrogeradores. Orientador: Rodrigo Melo e Silva de Oliveira; Coorientador: Victor Alexandrovich Dmitriev. 2014. 97 f. Dissertação (Mestrado em Engenharia Elétrica.) - Instituto de Tecnologia, Universidade Federal do Pará, Belém, 2014. Disponível em: http://repositorio.ufpa.br/jspui/handle/2011/9238. Acesso em:.
Resumo: Neste trabalho, é estabelecida uma metodologia baseada em análise espectral para localização de múltiplas descargas parciais na região dielétrica de bobinas de hidrogeradores. Esta localização de várias descargas objetiva viabilizar diagnóstico preventivo da região isolante da bobina. É concebido um modelo computacional utilizando-se o método das diferenças finitas no domínio do tempo para solucionar numericamente as equações de Maxwell, o qual é validado experimentalmente. O campo elétrico transitório associado a descargas parciais que ocorrem em diferentes posições da bobina é registrado e seu espectro, após processamento e análise estatística, é utilizado para realizar o diagnóstico. Em aproximadamente 90% das simulações realizadas, estimativas precisas da localização das descargas foram obtidas. Um novo método de injeção de sinais de descargas parciais também foi desenvolvido neste trabalho.
Abstract: A methodology based on spectral analysis is established for performing localization of multiple partial discharges in dielectric region of hydro-generators coils. This pinpointing of multiple discharges aims to provide means for performing preventive diagnosis of the insulating region of the referred coil. A computer model of the structure was conceived by using the finite-difference time-domain method (FDTD-3D) to numerically solve Maxwell’s equations, which is experimentally validated. The transient electric field associated with partial discharges that occur at different positions of the coil is calculated and its spectrum, after processing and statistical analysis, is used to perform the diagnosis. In approximately 90% of simulations, accurate estimates of simultaneous discharges location were obtained. Transient numerical results are in agreement with literatures measurements performed experimentally. A new method of injection of partial discharge signals was also developed in this work.
Palavras-chave: Hidrogerador
Método de diagnóstico
Descargas parciais na isolação
Análise espectral
Hydro-generator coils
Method of diagnosis
Partial discharges in isolation
Spectral analysis
CNPq: CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA::SISTEMAS ELETRICOS DE POTENCIA
País: Brasil
Instituição: Universidade Federal do Pará
Sigla da Instituição: UFPA
Instituto: Instituto de Tecnologia
Programa: Programa de Pós-Graduação em Engenharia Elétrica
Tipo de Acesso: Acesso Aberto
Aparece nas coleções:Dissertações em Engenharia Elétrica (Mestrado) - PPGEE/ITEC

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Dissertacao_MetodoEspectralLocalizacao.pdf35,89 MBAdobe PDFVisualizar/Abrir


Este item está licenciado sob uma Licença Creative Commons Creative Commons