Use este identificador para citar ou linkar para este item: https://repositorio.ufpa.br/jspui/handle/2011/10255
Tipo: Artigo de Periódico
Data do documento: Out-2011
Autor(es): SOUZA, Shirley do Socorro Melo de
OLIVEIRA, Dênio Ramam Carvalho de
Afiliação do(s) Autor(es): OLIVEIRA, D. R. C. Pós-Dr. Docente da Universidade Federal do Pará, Instituto de Tecnologia, Faculdade de Engenharia Civil
Título: Lajes lisas nervuradas de concreto armado ao cisalhamento
Título(s) alternativo(s): Reinforced concrete waffle flat slabs under shearing
Citar como: SOUZA, S. S. M.; OLIVEIRA, D. R. C.. Lajes lisas nervuradas de concreto armado ao cisalhamento. Revista Ibracon de Estrutura e Materiais, São Paulo, v. 4, n. 4, p. 627-641, out. 2011. Disponível em: <http://repositorio.ufpa.br/jspui/handle/2011/10255>. Acesso em:.
Resumo: Os sistemas estruturais com lajes lisas nervuradas são os mais utilizados no Brasil quando a exigência principal é a disponibilidade de "layouts" flexíveis e grandes vãos com razoável economia. Entretanto, poucos estudos foram realizados no Brasil considerando o comportamento destas lajes quando a resistência à flexão é satisfatória e as resistências ao cisalhamento nas nervuras e ao puncionamento tornam-se concorrentes. Este trabalho traz as análises experimentais de 8 lajes lisas nervuradas bidirecionais de concreto armado sujeitas a carregamento centrado. As dimensões das lajes foram constantes e iguais a 1.800 mm x 1.800 mm x 140 mm. As nervuras apresentaram 80 mm de altura por 50 mm de base e a resistência do concreto à compressão foi de aproximadamente 40 MPa. Os resultados foram comparados aos estimados pela norma brasileira NBR 6118:2003 1. Verificou-se que a resistência das nervuras não é satisfatoriamente estimada pela norma, subestimando demasiadamente os resultados para as nervuras sem e com armadura de cisalhamento.
Abstract: The structural systems with waffle flat slabs are the most used in Brazil when the main requirement is flexible "layouts" and long spans with reasonable economy. However, few studies have been developed in Brazil regarding the behavior of these slabs when the flexural resistance is satisfactory and the shear in the ribs and punching resistances become competitive. This work shows the experimental analysis of 8 two-way reinforced concrete waffle flat slabs under centered load. The dimensions of the slabs were the same and equal to 1800 mm x 1800 mm x 140 mm. The ribs were 80 mm (height) by 50 mm (width) and the compressive concrete strength was approximately 40 MPa. The experimental results were compared to those estimated by the Brazilian code NBR 6118:2003. It was verified that the resistance of the ribs is not satisfactorily estimated by the code, which excessively underestimates the results for ribs with and without shear reinforcement.
Palavras-chave: Concreto armado
Laje nervurada
Laje lisa
Cisalhamento
Punção
CNPq: CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
Título do Periódico: Revista IBRACON de Estruturas e Materiais
ISSN: 1983-4195
País: Brasil
Instituição: Universidade Federal do Pará
Sigla da Instituição: UFPA
Tipo de Acesso: Acesso Aberto
Fonte URI: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952011000400007&lng=pt&nrm=iso
Identificador DOI: http://dx.doi.org/10.1590/S1983-41952011000400007
Aparece nas coleções:Artigos Científicos - FEC/ITEC

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Artigo_LagesLisasNervuradas.pdfPORTUGUUÊS4,57 MBAdobe PDFVisualizar/Abrir
Article_ReinforcedConcreteWaffle.pdfINGLÊS4,41 MBAdobe PDFVisualizar/Abrir


Este item está licenciado sob uma Licença Creative Commons Creative Commons