Please use this identifier to cite or link to this item: https://repositorio.ufpa.br/jspui/handle/2011/11437
metadata.dc.type: Artigo de Periódico
Issue Date: Jun-2019
metadata.dc.creator: PEREIRA FILHO, Manoel José Mangabeira
FREITAS, Marcus Vinícius Pereira de
SANTOS, Douglas Freitas Augusto dos
FERREIRA, Maurício de Pina
NASCIMENTO, Alex J. C.
metadata.dc.description.affiliation: FREITAS, M. V. P., SANTOS D. F. A., NASCIMENTO, A. J. C., FERREIRA , M. P. Universidade Federal do Pará, Campus Universitário de Tucuruí (CAMTUC)
Title: Slabs strengthened for punching shear with post-installed steel and CFRP connectors
Other Titles: Lajes reforçadas à punção com conectores de aço e PRFC pós-instalados
Citation: PEREIRA FILHO, M. J. M. et al. Slabs strengthened for punching shear with post-installed steel and CFRP connectors. Revista IBRACON de Estruturas e Materiais, Brasília, DF, v. 12, n. 3, p. 445-478, maio/jun. 2019. DOI: http://dx.doi.org/10.1590/s1983-41952019000300002. Disponível em: http://repositorio.ufpa.br/jspui/handle/2011/11437. Acesso em:.
metadata.dc.description.resumo: Acidentes estruturais por punção vêm sendo relatados em edifícios com lajes lisas. As recomendações de projeto apresentadas pelas normas podem levar a estimativas de resistência à punção divergentes para situações semelhantes. Além disso, não são apresentadas orientações para o dimensionamento do reforço à punção de lajes existentes. Este artigo utiliza um banco de dados com 118 resultados experimentais para discutir o desempenho das estimativas teóricas de resistência à punção obtidas usando o ACI 318, o Eurocode 2 e a ABNT NBR 6118 para o caso de lajes sem armadura de cisalhamento. Um outro banco de dados, com resultados de 62 ensaios em lajes reforçadas com conectores pós-instalados de aço e PRFC, é utilizado para avaliar o desempenho destas técnicas de reforço e para apresentar propostas de adaptação das recomendações destas normas para permitir seu uso em situações de reforço à punção de ligações laje-pilar existentes.
Abstract: Structural accidents due to punching shear failures have been reported in flat slab buildings. Design recommendations presented by codes can lead to entirely different punching shear resistance esti-mates for similar situations. Furthermore, design codes do not present guidelines for the design of punching shear strengthening of existing slabs. This paper uses a database with 118 experimental re-sults to discuss the performance of theoretical estimates of punching shear resistance using ACI 318, Eurocode 2 and ABNT NBR 6118 in the case of slabs without shear reinforcement. Another database with results of 62 tests on slabs strengthened with post-installed steel and CFRP dowels is used to evaluate the performance of these strengthening techniques and to propose adaptations in codes to allow their use in punching shear strengthening situations of existing slab-column connections.
Keywords: Lajes lisas
Punção
Reforço estrutural
PRFC
Conectores pós-instalados de aço
Polímeros reforçados com fibra de carbono (PRFC)
Series/Report no.: Revista IBRACON de Estruturas e Materiais
ISSN: 1983-4195
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal do Pará
metadata.dc.publisher.initials: UFPA
metadata.dc.rights: Acesso Aberto
metadata.dc.source.uri: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000300445&lng=pt&nrm=iso#aff1
metadata.dc.identifier.doi: http://dx.doi.org/10.1590/s1983-41952019000300002
Appears in Collections:Artigos Científicos - CAMTUC

Files in This Item:
File Description SizeFormat 
Artigo_LajesReforcadasPuncao.pdfPORTUGUÊS2,6 MBAdobe PDFView/Open
Article_SlabsStrengthenedPunching.pdfINGLÊS3,6 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons