Use este identificador para citar ou linkar para este item:
https://repositorio.ufpa.br/jspui/handle/2011/11437
Tipo: | Artigo de Periódico |
Data do documento: | Jun-2019 |
Autor(es): | PEREIRA FILHO, Manoel José Mangabeira FREITAS, Marcus Vinícius Pereira de SANTOS, Douglas Freitas Augusto dos FERREIRA, Maurício de Pina NASCIMENTO, Alex J. C. |
Afiliação do(s) Autor(es): | FREITAS, M. V. P., SANTOS D. F. A., NASCIMENTO, A. J. C., FERREIRA , M. P. Universidade Federal do Pará, Campus Universitário de Tucuruí (CAMTUC) |
Título: | Slabs strengthened for punching shear with post-installed steel and CFRP connectors |
Título(s) alternativo(s): | Lajes reforçadas à punção com conectores de aço e PRFC pós-instalados |
Citar como: | PEREIRA FILHO, M. J. M. et al. Slabs strengthened for punching shear with post-installed steel and CFRP connectors. Revista IBRACON de Estruturas e Materiais, Brasília, DF, v. 12, n. 3, p. 445-478, maio/jun. 2019. DOI: http://dx.doi.org/10.1590/s1983-41952019000300002. Disponível em: http://repositorio.ufpa.br/jspui/handle/2011/11437. Acesso em:. |
Resumo: | Acidentes estruturais por punção vêm sendo relatados em edifícios com lajes lisas. As recomendações de projeto apresentadas pelas normas podem levar a estimativas de resistência à punção divergentes para situações semelhantes. Além disso, não são apresentadas orientações para o dimensionamento do reforço à punção de lajes existentes. Este artigo utiliza um banco de dados com 118 resultados experimentais para discutir o desempenho das estimativas teóricas de resistência à punção obtidas usando o ACI 318, o Eurocode 2 e a ABNT NBR 6118 para o caso de lajes sem armadura de cisalhamento. Um outro banco de dados, com resultados de 62 ensaios em lajes reforçadas com conectores pós-instalados de aço e PRFC, é utilizado para avaliar o desempenho destas técnicas de reforço e para apresentar propostas de adaptação das recomendações destas normas para permitir seu uso em situações de reforço à punção de ligações laje-pilar existentes. |
Abstract: | Structural accidents due to punching shear failures have been reported in flat slab buildings. Design recommendations presented by codes can lead to entirely different punching shear resistance esti-mates for similar situations. Furthermore, design codes do not present guidelines for the design of punching shear strengthening of existing slabs. This paper uses a database with 118 experimental re-sults to discuss the performance of theoretical estimates of punching shear resistance using ACI 318, Eurocode 2 and ABNT NBR 6118 in the case of slabs without shear reinforcement. Another database with results of 62 tests on slabs strengthened with post-installed steel and CFRP dowels is used to evaluate the performance of these strengthening techniques and to propose adaptations in codes to allow their use in punching shear strengthening situations of existing slab-column connections. |
Palavras-chave: | Lajes lisas Punção Reforço estrutural PRFC Conectores pós-instalados de aço Polímeros reforçados com fibra de carbono (PRFC) |
Título do Periódico: | Revista IBRACON de Estruturas e Materiais |
ISSN: | 1983-4195 |
País: | Brasil |
Instituição: | Universidade Federal do Pará |
Sigla da Instituição: | UFPA |
Tipo de Acesso: | Acesso Aberto |
Fonte URI: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000300445&lng=pt&nrm=iso#aff1 |
Identificador DOI: | http://dx.doi.org/10.1590/s1983-41952019000300002 |
Aparece nas coleções: | Artigos Científicos - CAMTUC |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Artigo_LajesReforcadasPuncao.pdf | PORTUGUÊS | 2,6 MB | Adobe PDF | Visualizar/Abrir |
Article_SlabsStrengthenedPunching.pdf | INGLÊS | 3,6 MB | Adobe PDF | Visualizar/Abrir |
Este item está licenciado sob uma Licença Creative Commons