Please use this identifier to cite or link to this item: https://repositorio.ufpa.br/jspui/handle/2011/8120
metadata.dc.type: Artigo de Periódico
Issue Date: Dec-2016
metadata.dc.creator: TAPAJOS, Luamim Sales
FERREIRA, José Augusto Tavares
LIMA NETO, Aarão Ferreira
TEIXEIRA, Marcelo Rassy
FERREIRA, Maurício de Pina
metadata.dc.description.affiliation: LIMA NETO, A.F.; TEIXEIRA, M.R.; FERREIRA, M.P. Universidade Federal do Pará
Title: Effect of wind in the design of reinforced concrete buildings
Other Titles: Efeito do vento no dimensionamento de edifícios de concreto armado
Citation: TAPAJOS, Luamim Sales et al. Effect of wind in the design of reinforced concrete buildings. Revista Ibracon de Estruturas e Materias, São Paulo, v. 9, n. 6, p. 883-910, nov./dez. 2016. Disponível em: <http://repositorio.ufpa.br/jspui/handle/2011/8120>. Acesso em:.
metadata.dc.description.resumo: Este artigo apresenta os resultados de um estudo paramétrico realizado com o objetivo de quantificar o tanto que erros na etapa de projeto relacionados com a consideração da ação do vento podem comprometer a resposta em serviço e a segurança de edifícios de concreto armado. Usando-se um modelo arquitetônico como referência e variando-se o número de pavimentos do edifício, a segurança estrutural foi avaliada como uma função da intensidade da ação do vento. Os resultados mostraram que mesmo para edifícios baixos, com 10 pavimentos, a desconsideração da ação do vento pode comprometer significativamente o comportamento e a segurança e que no caso de edifícios mais esbeltos, com até 30 pavimentos, pode levar a resultados catastróficos, como a ruína da estrutura através de colapso progressivo.
Abstract: This paper presents the results from a parametric study carried in order to quantify how far errors in the design stage related to the consideration of the wind action may put at risk the response and safety of reinforced concrete buildings. Using an architectural model as reference and varying the number of floors of the building, the structural safety was evaluated as a function of the wind action intensity. Results showed that even for low-rise buildings, with 10 floors, ignoring the wind action can significantly jeopardize their behaviour and safety. Yet, for slenderer buildings, up to 30 floors, it can lead to catastrophic results, as the ruin of the structure by progressive collapse.
Keywords: Velocidade do vento
Segurança estrutural
Edifícios
Concreto armado
Estudo paramétrico
Modelagem
Series/Report no.: Revista IBRACON de Estruturas e Materiais
ISSN: 1983-4195
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal do Pará
metadata.dc.publisher.initials: UFPA
metadata.dc.rights: Acesso Aberto
metadata.dc.source.uri: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952016000600883&lng=pt&nrm=iso
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952016000600883&lng=pt&nrm=iso&tlng=pt
metadata.dc.identifier.doi: http://dx.doi.org/10.1590/s1983-41952016000600005
Appears in Collections:Artigos Científicos - ITEC

Files in This Item:
File Description SizeFormat 
Artigo_EffectWindDesign.pdfINGLÊS3,35 MBAdobe PDFView/Open
Artigo_EfeitoVentoDimensionamento.pdfPORTUGUÊS3,29 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons