Please use this identifier to cite or link to this item: https://repositorio.ufpa.br/jspui/handle/2011/10257
metadata.dc.type: Dissertação
Issue Date: 11-Jun-2018
metadata.dc.creator: MARCILLO, Kevin Eduardo Lucas
metadata.dc.contributor.advisor1: BARRA JUNIOR, Walter
Title: Performance evaluation of robust parametric control strategies applied on suppression of oscillations effects due to constant power loads in multi-converter buck-buck systems
Other Titles: Avaliação de desempenho de estratégias de controle paramétrico robusto aplicadas na supressão de efeitos de oscilações devido a cargas de potência constantes em sistemas de buck-buck multi-conversor
metadata.dc.description.sponsorship: 
Citation: MARCILLO, Kevin Eduardo Lucas. Performance evaluation of robust parametric control strategies applied on suppression of oscillations effects due to constant power loads in multi-converter buck-buck systems.Orientador: Walter Barra Júnior. Belém, 84 f. Dissertação (Mestrado em Engenharia Elétrica) - Instituto de Tecnologia, Universidade Federal do Pará, , Belém, 2018. Programa de Pós-Graduação. Disponível em: <http://repositorio.ufpa.br/jspui/handle/2011/10257>. Acesso em:.
metadata.dc.description.resumo: Conversores chaveados são sistemas amplamente utilizadas em aplicações industriais. Tais sistemas operam via controle em malha fechada e, dessa forma, os aspectos de estabilidade e desempenho em malha fechada devem ser assegurados pelo projetista. Recentemente, o emprego de sistemas com múltiplos conversores vem se tornando comum em uma ampla gama de aplicações. A interação entre os sistemas de controle os múltiplos conversores pode levar o sistema a operar com reduzidas margens de estabilidade ou com um baixo desempenho dinâmico. Portanto, a estabilidade de um sistema com conversores operando em cascata é uma grande preocupação para aplicações reais. A instabilidade em sistemas em cascata pode ocorrer devido à carga de potência constante (CPL), que é um comportamento dos conversores quando se encontram regulados. As CPLs exibem comportamento de resistência negativa incremental, causando um alto risco de instabilidade em conversores interligados. Dessa forma, a mitigação desse problema é uma questão importante no projeto da fonte de alimentação comutada de múltiplos estágios, de modo a garantir a estabilidade de todo o sistema. No entanto, algumas dificuldades estão presentes além da CPL, por exemplo, não linearidades fortes, devido à presença do elemento indutivo, além das incertezas em relação aos valores nominais dos componentes discretos que compõem o sistema. Neste trabalho é realizado um estudo experimental do desempenho das metodologias de controle robusto paramétrico aplicadas ao problema de mitigar o efeito adverso de cargas do tipo CPL, em um sistema com dois conversores buck operando em cascata (sistema buck-buck). Vários testes foram desenvolvidos utilizando tanto uma planta experimental quanto via simulação computacional em Matlab/ Simulink, quando o sistema multiconversor buck-buck é submetido a uma variação de potência. Os resultados mostram o melhor desempenho das metodologias propostas.
Abstract: Multi-converter electronic systems are becoming widely used in many industrial applications; therefore, the stability of the cascaded system is a big concern to real-world power supplies applications. Instability in cascaded systems may occur due to the constant power load (CPL), which is a behavior of the tightly regulated converters. CPLs exhibit incremental negative resistance behavior causing a high risk of instability in interconnected converters; therefore, the mitigation of this problem is an important issue in the multiple-stage switched mode power supply design. Thus, it is important to guarantee stability of the whole system. However, some difficulties remains besides the CPL, e.g., non-linearities due to the inductive element and uncertainties due to imprecision of mathematical models and/or variation of nominal values of the discrete elements that compose the DC/DC buck converter. Aiming to evaluate the performance of the proposed robust methodologies in this work to mitigate the instability problem caused by a CPL, several tests were developed by using an experimental plant and Matlab/Simulink, when the multi-converter buck-buck system is subjected a variation of power reference. The results show the improved performance of the proposed methodologies.
Keywords: Sistema multiconversor
Controle robusto paramétrico
CPL - Carga de energia constante
Variação paramétrica
Teorema de estabilidade de kharitonov
Teorema de Chebyshev
Multi-converter system
Robust control
Robust parametric control
CPL - Constant power load
Parametric variation
Kharitonov stability theorem
Chebyshev theorem
Buck converter
metadata.dc.subject.areadeconcentracao: SISTEMAS DE ENERGIA ELÉTRICA
metadata.dc.subject.linhadepesquisa: CONTROLE E AUTOMAÇÃO
metadata.dc.subject.cnpq: CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA::ELETRONICA INDUSTRIAL, SISTEMAS E CONTROLES ELETRONICOS::CONTROLE DE PROCESSOS ELETRONICOS, RETROALIMENTACAO
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal do Pará
metadata.dc.publisher.initials: UFPA
metadata.dc.publisher.department: Instituto de Tecnologia
metadata.dc.publisher.program: Programa de Pós-Graduação em Engenharia Elétrica
metadata.dc.rights: Acesso Aberto
metadata.dc.source: 1 CD-ROM
Appears in Collections:Dissertações em Engenharia Elétrica (Mestrado) - PPGEE/ITEC

Files in This Item:
File Description SizeFormat 
Dissertacao_PerfomanceEvaluationRobust.pdf5,19 MBAdobe PDFView/Open